제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA208Hu

Magnetic Luminex Assay Kit for Pyruvate kinase isozymes R/L (PKLR) ,etc.

Magnetic Luminex Assay Kit for Pyruvate kinase isozymes R/L (PKLR) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA208Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

2.44-2500pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.813 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Pyruvate kinase isozymes R/L (PKLR) ,etc..
No significant cross-reactivity or interference between Pyruvate kinase isozymes R/L (PKLR) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Pyruvate kinase isozymes R/L (PKLR) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Pyruvate kinase isozymes R/L (PKLR) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-101 89
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 89-99 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Pyruvate kinase isozymes R/L (PKLR) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Pyruvate kinase isozymes R/L (PKLR) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pyruvate kinase isozymes R/L (PKLR) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 96-104% 85-99% 81-89%
EDTA plasma(n=5) 78-92% 93-101% 94-102% 80-89%
heparin plasma(n=5) 96-105% 89-99% 84-99% 88-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PKLR) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Onco Targets Ther The effects of PGC-1α on the proliferation and energy metabolism of malignant endometrial cancer cells PubMed: 25914546
european journal of endocrinology Contact system activation and high thrombin generation in hyperthyroidism. pubmed:28137735
CELLULAR AND MOLECULAR NEUROBIOLOGY Time-Dependent Changes in the Serum Levels of Neurobiochemical Factors After Acute Methadone Overdose in Adolescent Male Rat Pubmed: 32712727
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA208Hu01 Recombinant Pyruvate kinase isozymes R/L (PKLR) Positive Control; Immunogen; SDS-PAGE; WB.
PAA208Hu01 Polyclonal Antibody to Pyruvate kinase isozymes R/L (PKLR) WB; IHC; ICC; IP.
MAA208Hu22 Monoclonal Antibody to Pyruvate kinase isozymes R/L (PKLR) WB; IHC; ICC; IP.
SEA208Hu ELISA Kit for Pyruvate kinase isozymes R/L (PKLR) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA208Hu Magnetic Luminex Assay Kit for Pyruvate kinase isozymes R/L (PKLR) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기