SKU(재고 관리 코드):LMA526Ge
Magnetic Luminex Assay Kit for Platelet Activating Factor (PAF) ,etc.
Magnetic Luminex Assay Kit for Platelet Activating Factor (PAF) ,etc.
Product No.
LMA526Ge
Organism Species
Pan-species (General).
Sample Type
Serum, plasma and other biological fluids
Test Method
Competitive Inhibition
Assay Length
1.5h
Detection Range
2.93-3000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.977 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Platelet Activating Factor (PAF) ,etc..
No significant cross-reactivity or interference between Platelet Activating Factor (PAF) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Platelet Activating Factor (PAF) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Activating Factor (PAF) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 92-103 | 97 |
EDTA plasma(n=5) | 79-99 | 89 |
heparin plasma(n=5) | 97-104 | 101 |
sodium citrate plasma(n=5) | 79-90 | 83 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Activating Factor (PAF) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Activating Factor (PAF) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Activating Factor (PAF) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 97-105% | 85-99% | 95-102% | 80-101% |
EDTA plasma(n=5) | 79-97% | 81-97% | 90-98% | 85-99% |
heparin plasma(n=5) | 87-105% | 91-99% | 87-94% | 92-101% |
sodium citrate plasma(n=5) | 81-105% | 78-94% | 89-96% | 99-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PAF) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
PLOS ONE | Lysophosphatidylcholine Acyltransferase1 Overexpression Promotes Oral Squamous Cell Carcinoma Progression via Enhanced Biosynthesis of Platelet-Activating Factor Pubmed:25803864 |
J Biol Chem. | Platelet-activating factor contributes to Bacillus anthracis lethal toxin-associated damage. Pubmed:24478317 |
Mediators of Inflammation | Mediators of Mast Cells in Bullous Pemphigoid and Dermatitis Herpetiformis Pubmed:25400334 |
Molecular Medicine Reports | Comparing the role of Ginkgolide B and Ginkgolide K on cultured astrocytes exposed to oxygen‑glucose deprivation Pubmed: 30221704 |
BioMed Research International | Chlorogenic Acid Attenuates Dextran Sodium Sulfate-Induced Ulcerative Colitis in Mice through MAPK/ERK/JNK Pathway |
Contraception | Antifertility effectiveness of a novel polymer matrix composite and its influence on the endometrium in rhesus macaques (Macaca mulatta) Pubmed: 30980831 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CEA526Ge | ELISA Kit for Platelet Activating Factor (PAF) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA526Ge | Magnetic Luminex Assay Kit for Platelet Activating Factor (PAF) ,etc. | Magnetic Luminex Assay for Antigen Detection. |