SKU(재고 관리 코드):LMB041Ra
Magnetic Luminex Assay Kit for Vitronectin (VTN) ,etc.
Magnetic Luminex Assay Kit for Vitronectin (VTN) ,etc.
Product No.
LMB041Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.1-100ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.033 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Vitronectin (VTN) ,etc..
No significant cross-reactivity or interference between Vitronectin (VTN) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Vitronectin (VTN) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Vitronectin (VTN) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 84-97 | 88 |
EDTA plasma(n=5) | 86-93 | 90 |
heparin plasma(n=5) | 79-90 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vitronectin (VTN) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vitronectin (VTN) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vitronectin (VTN) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 95-104% | 98-105% | 79-101% | 93-102% |
EDTA plasma(n=5) | 90-101% | 97-105% | 80-89% | 79-89% |
heparin plasma(n=5) | 88-102% | 86-102% | 99-105% | 91-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:VTN) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Biomedical Engineering and Informatics | Application of iTRAQ quantitative proteomics in identification of serum biomarkers in breast cancer IEEE: 6098563 |
PLoS ONE | Identification of Altered Plasma Proteins by Proteomic Study in Valvular Heart Diseases and the Potential Clinical Significance PubMed: PMC3754973 |
Liver International | Identification of candidate biomarkers for hepatocellular carcinoma in plasma of HCV-infected cirrhotic patients by 2-D DIGE Pubmed: 23944848 |
Analytical Biochemistry | A multianalytical approach to investigate the effect of nanofiltration on plasma-derived factor IX clinical lots Pubmed:29154788 |
Journal of Materials Chemistry B | Serum protein adsorption profile on BCP ceramic and influence of the elevated adsorption of adhesive proteins on the behaviour of MSCs Doi: 10.1039/C8TB02283F |
JOURNAL OF NEPHROLOGY | Urinary vitronectin identifies patients with high levels of fibrosis in kidney grafts 33275196 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPB041Ra01 | Recombinant Vitronectin (VTN) | Positive Control; Immunogen; SDS-PAGE; WB. |
APB041Ra01 | Active Vitronectin (VTN) | Cell culture; Activity Assays. |
PAB041Ra01 | Polyclonal Antibody to Vitronectin (VTN) | WB; IHC; ICC; IP. |
MAB041Ra21 | Monoclonal Antibody to Vitronectin (VTN) | WB; IHC; ICC; IP. |
SEB041Ra | ELISA Kit for Vitronectin (VTN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB041Ra | Magnetic Luminex Assay Kit for Vitronectin (VTN) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSB041Ra01 | ELISA Kit DIY Materials for Vitronectin (VTN) | Main materials for "Do It (ELISA Kit) Yourself". |