제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB041Mu

Magnetic Luminex Assay Kit for Vitronectin (VTN) ,etc.

Magnetic Luminex Assay Kit for Vitronectin (VTN) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB041Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Plasma.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.39-400ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.13 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Vitronectin (VTN) ,etc..
No significant cross-reactivity or interference between Vitronectin (VTN) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Vitronectin (VTN) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Vitronectin (VTN) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-94 90
EDTA plasma(n=5) 84-91 88
heparin plasma(n=5) 83-95 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vitronectin (VTN) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vitronectin (VTN) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vitronectin (VTN) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-88% 85-98% 87-101% 85-101%
EDTA plasma(n=5) 78-95% 94-102% 91-99% 96-105%
heparin plasma(n=5) 81-102% 98-105% 96-105% 86-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:VTN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Biomedical Engineering and Informatics Application of iTRAQ quantitative proteomics in identification of serum biomarkers in breast cancer IEEE: 6098563
PLoS ONE Identification of Altered Plasma Proteins by Proteomic Study in Valvular Heart Diseases and the Potential Clinical Significance PubMed: PMC3754973
Liver International Identification of candidate biomarkers for hepatocellular carcinoma in plasma of HCV-infected cirrhotic patients by 2-D DIGE Pubmed: 23944848
Analytical Biochemistry A multianalytical approach to investigate the effect of nanofiltration on plasma-derived factor IX clinical lots Pubmed:29154788
Journal of Materials Chemistry B Serum protein adsorption profile on BCP ceramic and influence of the elevated adsorption of adhesive proteins on the behaviour of MSCs Doi: 10.1039/C8TB02283F 
JOURNAL OF NEPHROLOGY Urinary vitronectin identifies patients with high levels of fibrosis in kidney grafts 33275196
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB041Mu01 Recombinant Vitronectin (VTN) Positive Control; Immunogen; SDS-PAGE; WB.
RPB041Mu02 Recombinant Vitronectin (VTN) Positive Control; Immunogen; SDS-PAGE; WB.
PAB041Mu01 Polyclonal Antibody to Vitronectin (VTN) WB; IHC; ICC; IP.
PAB041Mu02 Polyclonal Antibody to Vitronectin (VTN) WB; IHC; ICC; IP.
SEB041Mu ELISA Kit for Vitronectin (VTN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB041Mu Magnetic Luminex Assay Kit for Vitronectin (VTN) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기