SKU(재고 관리 코드):LMA633Mu
Magnetic Luminex Assay Kit for Platelet Derived Growth Factor BB (PDGF BB) ,etc.
Magnetic Luminex Assay Kit for Platelet Derived Growth Factor BB (PDGF BB) ,etc.
Product No.
LMA633Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Serum, plasma and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.01-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.003 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Platelet Derived Growth Factor BB (PDGF BB) ,etc..
No significant cross-reactivity or interference between Platelet Derived Growth Factor BB (PDGF BB) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Platelet Derived Growth Factor BB (PDGF BB) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Derived Growth Factor BB (PDGF BB) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 79-91 | 87 |
EDTA plasma(n=5) | 81-102 | 89 |
heparin plasma(n=5) | 90-97 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Derived Growth Factor BB (PDGF BB) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Derived Growth Factor BB (PDGF BB) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Derived Growth Factor BB (PDGF BB) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-101% | 79-92% | 91-101% | 86-93% |
EDTA plasma(n=5) | 78-95% | 85-96% | 90-98% | 79-96% |
heparin plasma(n=5) | 90-98% | 80-104% | 92-101% | 95-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PDGF BB) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Therapeutics and Clinical Risk Management | Elevated blood plasma levels of epinephrine, norepinephrine, tyrosine hydroxylase, TGFβ1, and TNFα associated with high-altitude pulmonary edema in an Indian population. pubmed:27540296 |
PeerJ | Platelet-rich concentrate in serum free medium enhances osteogenic differentiation of bone marrow-derived human mesenchymal stromal cells pubmed:27651984 |
Biosens Bioelectron | A biolayer interferometry-based enzyme-linked aptamer sorbent assay for real-time and highly sensitive detection of PDGF-BB pubmed:29125972 |
Anticancer Research | Association Between Endothelial Progenitor Cells and Treatment Response in Non-Squamous Non-small Cell Lung Cancer Treated with Bevacizumab. pubmed:28982871 |
EBioMedicine | Modulating endothelial adhesion and migration impacts stem cell therapies efficacy Pubmed: 32942121 |
sensors and actuators b-chemical | A light-induced self-powered competitive immunosensor for the detection of platelet derived growth factor-BB via an elaborately assembled bioconjugate |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA633Mu01 | Recombinant Platelet Derived Growth Factor BB (PDGF BB) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA633Mu01 | Polyclonal Antibody to Platelet Derived Growth Factor BB (PDGF BB) | WB; IHC; ICC; IP. |
LAA633Mu71 | Biotin-Linked Polyclonal Antibody to Platelet Derived Growth Factor BB (PDGF BB) | WB; IHC; ICC. |
LAA633Mu81 | FITC-Linked Polyclonal Antibody to Platelet Derived Growth Factor BB (PDGF BB) | WB; IHC; ICC; IF. |
MEA633Mu | Mini Samples ELISA Kit for Platelet Derived Growth Factor BB (PDGF BB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEA633Mu | ELISA Kit for Platelet Derived Growth Factor BB (PDGF BB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA633Mu | Magnetic Luminex Assay Kit for Platelet Derived Growth Factor BB (PDGF BB) ,etc. | Magnetic Luminex Assay for Antigen Detection. |