Magnetic Luminex Assay Kit for Hemojuvelin (HJV) ,etc.
Magnetic Luminex Assay Kit for Hemojuvelin (HJV) ,etc.
Product No.
LMB995Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Serum, plasma and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.04-40ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.013 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Hemojuvelin (HJV) ,etc..
No significant cross-reactivity or interference between Hemojuvelin (HJV) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Hemojuvelin (HJV) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Hemojuvelin (HJV) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 96-105 | 102 |
EDTA plasma(n=5) | 79-91 | 83 |
heparin plasma(n=5) | 78-89 | 80 |
sodium citrate plasma(n=5) | 83-95 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemojuvelin (HJV) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemojuvelin (HJV) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemojuvelin (HJV) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 90-101% | 78-99% | 81-97% | 89-98% |
EDTA plasma(n=5) | 95-102% | 99-105% | 83-101% | 98-105% |
heparin plasma(n=5) | 90-97% | 90-98% | 92-101% | 87-101% |
sodium citrate plasma(n=5) | 87-95% | 97-104% | 83-101% | 88-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:HJV) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
PLoS One. | Effect of Iron Overload and Iron Deficiency on Liver Hemojuvelin Protein PubMed: PMC3356351 |
Journal of | Hepcidin Levels Are Increased in Patients with Acute Ischemic Stroke: Preliminary Report PubMed: 25881778 |
European Journal of Haematology | Soluble hemojuvelin in transfused and untransfused thalassaemic subjects doi:10.1111 |
American Journal of Nephrology | The secret war against counterfeit science pubmed:28492262 |
Critical Care | Urinary biomarkers predict advanced acute kidney injury after cardiovascular surgery Pubmed:29699579 |
Scientific Reports | Hemojuvelin Predicts Acute Kidney Injury and Poor Outcomes Following Cardiac Surgery Pubmed:29386545 |
Journal of Cerebral Blood Flow and Metabolism | The functional role of hemojuvelin in acute ischemic stroke Pubmed: 31307288 |
Oxidative damage and iron dyshomeostasis in thalassemic patients | |
J Trace Elem Med Biol | Caffeine and alcohol-friends or foes of human iron stores? Pubmed:35063815 |
Arch Pathol Lab Med | Urinary Biomarkers Can Predict Weaning From Acute Dialysis Therapy in Critically Ill Patients Pubmed:35311928 |
Arch Pathol Lab Med | The Relationships among Plasma Fetuin-B, Thyroid Autoimmunity, and Fertilization Rate In Vitro Fertilization and Embryo Transfer Pubmed:35340679 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPB995Mu02 | Recombinant Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPB995Mu01 | Recombinant Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB995Mu01 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
PAB995Mu02 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
SEB995Mu | ELISA Kit for Hemojuvelin (HJV) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB995Mu | Magnetic Luminex Assay Kit for Hemojuvelin (HJV) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSB995Mu01 | ELISA Kit DIY Materials for Hemojuvelin (HJV) | Main materials for "Do It (ELISA Kit) Yourself". |