제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMJ282Hu

Magnetic Luminex Assay Kit for DNA Damage Inducible Transcript 3 (DDIT3) ,etc.

Magnetic Luminex Assay Kit for DNA Damage Inducible Transcript 3 (DDIT3) ,etc.

Detection range
Size
Sensitivity

Product No.

LMJ282Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.02-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.007 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of DNA Damage Inducible Transcript 3 (DDIT3) ,etc..
No significant cross-reactivity or interference between DNA Damage Inducible Transcript 3 (DDIT3) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant DNA Damage Inducible Transcript 3 (DDIT3) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of DNA Damage Inducible Transcript 3 (DDIT3) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-94 89
EDTA plasma(n=5) 92-101 97
heparin plasma(n=5) 85-99 91
sodium citrate plasma(n=5) 84-105 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level DNA Damage Inducible Transcript 3 (DDIT3) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level DNA Damage Inducible Transcript 3 (DDIT3) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DNA Damage Inducible Transcript 3 (DDIT3) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-101% 82-94% 94-104% 95-105%
EDTA plasma(n=5) 99-105% 79-90% 90-98% 88-98%
heparin plasma(n=5) 80-102% 83-105% 96-105% 97-105%
sodium citrate plasma(n=5) 87-103% 86-95% 88-101% 78-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:DDIT3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
The Showa University Journal of Medical Sciences Combined Neuroprotective Effects of Propofol and Dexmedetomidine on Endoplasmic Reticulum Stress-mediated Apoptosis in SH-SY5Y Cells 28_219
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPJ282Hu01 Recombinant DNA Damage Inducible Transcript 3 (DDIT3) Positive Control; Immunogen; SDS-PAGE; WB.
PAJ282Hu01 Polyclonal Antibody to DNA Damage Inducible Transcript 3 (DDIT3) WB; IHC
LAJ282Hu71 Biotin-Linked Polyclonal Antibody to DNA Damage Inducible Transcript 3 (DDIT3) WB; IHC; ICC.
MAJ282Hu21 Monoclonal Antibody to DNA Damage Inducible Transcript 3 (DDIT3) WB; IHC; ICC; IP.
SEJ282Hu ELISA Kit for DNA Damage Inducible Transcript 3 (DDIT3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMJ282Hu Magnetic Luminex Assay Kit for DNA Damage Inducible Transcript 3 (DDIT3) ,etc. Magnetic Luminex Assay for Antigen Detection.
PGJ282Hu01 Primer Pair for DNA Damage Inducible Transcript 3 (DDIT3) PCR
전체 세부 정보 보기