SKU(재고 관리 코드):LMB402Hu

Magnetic Luminex Assay Kit for Fc Fragment Of IgA Receptor (FcaR) ,etc.

Magnetic Luminex Assay Kit for Fc Fragment Of IgA Receptor (FcaR) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB402Hu

Organism Species

Homo sapiens (Human).

Sample Type

serum, plasma, tissue homogenates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.05-50ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.05-50ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Fc Fragment Of IgA Receptor (FcaR) ,etc..
No significant cross-reactivity or interference between Fc Fragment Of IgA Receptor (FcaR) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Fc Fragment Of IgA Receptor (FcaR) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Fc Fragment Of IgA Receptor (FcaR) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-94 90
EDTA plasma(n=5) 95-104 99
heparin plasma(n=5) 85-101 95
sodium citrate plasma(n=5) 78-101 88

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fc Fragment Of IgA Receptor (FcaR) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fc Fragment Of IgA Receptor (FcaR) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fc Fragment Of IgA Receptor (FcaR) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 85-99% 94-104% 87-94%
EDTA plasma(n=5) 85-99% 94-101% 95-102% 94-105%
heparin plasma(n=5) 82-103% 93-101% 91-104% 82-93%
sodium citrate plasma(n=5) 98-105% 86-94% 79-89% 93-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:FcaR) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
BBA Clinical Urinary myeloid IgA Fc alpha receptor (CD89) and transglutaminase-2 as new biomarkers for active IgA nephropathy and henoch-Schönlein purpura nephritis Pubmed:27051593
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB402Hu01 Recombinant Fc Fragment Of IgA Receptor (FcaR) Positive Control; Immunogen; SDS-PAGE; WB.
PAB402Hu01 Polyclonal Antibody to Fc Fragment Of IgA Receptor (FcaR) WB; IHC; ICC; IP.
FAB402Hu01 Anti-Fc Fragment Of IgA Receptor (FcaR) Polyclonal Antibody Flow cytometry.
MAB402Hu22 Monoclonal Antibody to Fc Fragment Of IgA Receptor (FcaR) WB; IHC; ICC; IP.
SEB402Hu ELISA Kit for Fc Fragment Of IgA Receptor (FcaR) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB402Hu Magnetic Luminex Assay Kit for Fc Fragment Of IgA Receptor (FcaR) ,etc. Magnetic Luminex Assay for Antigen Detection.