SKU(재고 관리 코드):LMA959Hu
Magnetic Luminex Assay Kit for L1-Cell Adhesion Molecule (L1CAM) ,etc.
Magnetic Luminex Assay Kit for L1-Cell Adhesion Molecule (L1CAM) ,etc.
Product No.
LMA959Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.01-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.003 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of L1-Cell Adhesion Molecule (L1CAM) ,etc..
No significant cross-reactivity or interference between L1-Cell Adhesion Molecule (L1CAM) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant L1-Cell Adhesion Molecule (L1CAM) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of L1-Cell Adhesion Molecule (L1CAM) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-103 | 99 |
EDTA plasma(n=5) | 80-103 | 86 |
heparin plasma(n=5) | 78-91 | 84 |
sodium citrate plasma(n=5) | 97-104 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level L1-Cell Adhesion Molecule (L1CAM) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level L1-Cell Adhesion Molecule (L1CAM) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of L1-Cell Adhesion Molecule (L1CAM) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-98% | 78-96% | 78-97% | 97-105% |
EDTA plasma(n=5) | 97-105% | 91-99% | 91-98% | 87-102% |
heparin plasma(n=5) | 79-102% | 80-97% | 78-93% | 94-102% |
sodium citrate plasma(n=5) | 89-96% | 98-105% | 85-99% | 80-90% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:L1CAM) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Arch Gynecol Obstet. | The sL1CAM in sera of patients with endometrial and ovarian cancers. pubmed:27832351 |
Journal of Neurotrauma | L1CAM overexpression downregulates phosphacan and upregulates structural plasticity-related genes rostral and caudal to the complete spinal cord transection Pubmed: 31426714 |
Cancers | Extracellular Vesicles-Based Biomarkers Represent a Promising Liquid Biopsy in Endometrial Cancer Pubmed: 31842290 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPA959Hu01 | Recombinant L1-Cell Adhesion Molecule (L1CAM) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA959Hu02 | Recombinant L1-Cell Adhesion Molecule (L1CAM) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA959Hu01 | Polyclonal Antibody to L1-Cell Adhesion Molecule (L1CAM) | WB; IHC; ICC; IP. |
PAA959Hu02 | Polyclonal Antibody to L1-Cell Adhesion Molecule (L1CAM) | WB; IHC; ICC; IP. |
LAA959Hu71 | Biotin-Linked Polyclonal Antibody to L1-Cell Adhesion Molecule (L1CAM) | WB; IHC; ICC. |
MAA959Hu22 | Monoclonal Antibody to L1-Cell Adhesion Molecule (L1CAM) | WB; IHC; ICC; IP. |
SEA959Hu | ELISA Kit for L1-Cell Adhesion Molecule (L1CAM) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA959Hu | Magnetic Luminex Assay Kit for L1-Cell Adhesion Molecule (L1CAM) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSA959Hu01 | ELISA Kit DIY Materials for L1-Cell Adhesion Molecule (L1CAM) | Main materials for "Do It (ELISA Kit) Yourself". |