SKU(재고 관리 코드):LMA588Ra
Magnetic Luminex Assay Kit for Pyruvate kinase isozymes M2 (PKM2) ,etc.
Magnetic Luminex Assay Kit for Pyruvate kinase isozymes M2 (PKM2) ,etc.
Product No.
LMA588Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.03-30ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.01 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Pyruvate kinase isozymes M2 (PKM2) ,etc..
No significant cross-reactivity or interference between Pyruvate kinase isozymes M2 (PKM2) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Pyruvate kinase isozymes M2 (PKM2) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Pyruvate kinase isozymes M2 (PKM2) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 92-101 | 97 |
EDTA plasma(n=5) | 88-96 | 93 |
heparin plasma(n=5) | 97-104 | 101 |
sodium citrate plasma(n=5) | 85-92 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Pyruvate kinase isozymes M2 (PKM2) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Pyruvate kinase isozymes M2 (PKM2) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pyruvate kinase isozymes M2 (PKM2) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 93-101% | 80-99% | 96-104% | 82-90% |
EDTA plasma(n=5) | 78-95% | 89-103% | 80-94% | 95-102% |
heparin plasma(n=5) | 95-103% | 81-96% | 93-101% | 80-95% |
sodium citrate plasma(n=5) | 98-105% | 85-94% | 90-101% | 96-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PKM2) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Cancer Research | Antigen Presentation by Dendritic Cells in Tumors Is Disrupted by Altered Metabolism that Involves Pyruvate Kinase M2 and Its Interaction with SOCS3 AACR: 70189 |
Molecular BioSystems | Abnormal levels of heterogeneous nuclear ribonucleoprotein A2B1 (hnRNPA2B1) in tumour tissue and blood samples from patients diagnosed with lung cancer Pubmed:25483567 |
Tumour Biol | M2 isoform of pyruvate kinase (PKM2) is upregulated in Kazakh’s ESCC and promotes proliferation and migration of ESCC cells PubMed: 26404132 |
Oncotarget | Identification of a serum biomarker panel for the differential diagnosis of cholangiocarcinoma and primary sclerosing cholangitis Pubmed:29707118 |
Journal of Neurotrauma | Acteoside improves muscle atrophy and motor function by inducing new myokine secretion in chronic spinal cord injury Pubmed: 30318996 |
Cell Reports | Secreted Pyruvate Kinase M2 Promotes Lung Cancer Metastasis through Activating the Integrin Beta1/FAK Signaling Pathway Pubmed: 32049010 |
Chrysin serves as a novel inhibitor of DGKα/FAK interaction to suppress the malignancy of esophageal squamous cell carcinoma (ESCC) | |
Cancer Cell International | Bufalin Induced Mitochondrial Dysfunction Promotes Apoptosis of Glioma Cells by Regulating Annexin A2 and DRP1 Proteins |
Cancer Cell Int | Bufalin induces mitochondrial dysfunction and promotes apoptosis of glioma cells by regulating Annexin A2 and DRP1 protein expression 34376212 |
Life (Basel) | Putative Association between Low Baseline Gene Expression in the Peripheral Blood and Clinical Remission in Rheumatoid Arthritis Patients Treated with Tofacitinib 34947916 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA588Ra01 | Recombinant Pyruvate kinase isozymes M2 (PKM2) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA588Ra01 | Polyclonal Antibody to Pyruvate kinase isozymes M2 (PKM2) | WB; IHC; ICC; IP. |
FAA588Ra01 | Anti-Pyruvate kinase isozymes M2 (PKM2) Polyclonal Antibody | Flow cytometry. |
MAA588Ra21 | Monoclonal Antibody to Pyruvate kinase isozymes M2 (PKM2) | WB; IHC; ICC; IP. |
SEA588Ra | ELISA Kit for Pyruvate kinase isozymes M2 (PKM2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA588Ra | Magnetic Luminex Assay Kit for Pyruvate kinase isozymes M2 (PKM2) ,etc. | Magnetic Luminex Assay for Antigen Detection. |