제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMC629Hu

Magnetic Luminex Assay Kit for Methionine Sulfoxide Reductase A (MSRA) ,etc.

Magnetic Luminex Assay Kit for Methionine Sulfoxide Reductase A (MSRA) ,etc.

Detection range
Size
Sensitivity

Product No.

LMC629Hu

Organism Species

Homo sapiens (Human).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

Specificity

This assay has high sensitivity and excellent specificity for detection of Methionine Sulfoxide Reductase A (MSRA) ,etc..
No significant cross-reactivity or interference between Methionine Sulfoxide Reductase A (MSRA) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Methionine Sulfoxide Reductase A (MSRA) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Methionine Sulfoxide Reductase A (MSRA) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-102 99
EDTA plasma(n=5) 89-96 92
heparin plasma(n=5) 78-99 89

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Methionine Sulfoxide Reductase A (MSRA) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Methionine Sulfoxide Reductase A (MSRA) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Methionine Sulfoxide Reductase A (MSRA) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-94% 88-99% 97-105% 78-92%
EDTA plasma(n=5) 98-105% 83-104% 84-95% 82-96%
heparin plasma(n=5) 86-104% 79-96% 94-101% 78-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:MSRA) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Chem Biol Interact Dysfunction of methionine sulfoxide reductases to repair damaged proteins by nickel nanoparticles PubMed: 25979628
Scientific Reports Protein oxidation and degradation caused by particulate matter. pubmed:27644844
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC629Hu01 Recombinant Methionine Sulfoxide Reductase A (MSRA) Positive Control; Immunogen; SDS-PAGE; WB.
PAC629Hu01 Polyclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB,IHC,ICC/IF
MAC629Hu21 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu22 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu23 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu24 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu25 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu27 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
SEC629Hu ELISA Kit for Methionine Sulfoxide Reductase A (MSRA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC629Hu Magnetic Luminex Assay Kit for Methionine Sulfoxide Reductase A (MSRA) ,etc. Magnetic Luminex Assay for Antigen Detection.
PGC629Hu01 Primer Pair for Methionine Sulfoxide Reductase A (MSRA) PCR
전체 세부 정보 보기