제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMA985Mu

Magnetic Luminex Assay Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc.

Magnetic Luminex Assay Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA985Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc..
No significant cross-reactivity or interference between P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-104 101
EDTA plasma(n=5) 89-101 97
heparin plasma(n=5) 97-105 102
sodium citrate plasma(n=5) 92-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 91-98% 78-105% 85-94%
EDTA plasma(n=5) 78-103% 91-101% 89-97% 96-103%
heparin plasma(n=5) 86-94% 90-97% 78-102% 91-98%
sodium citrate plasma(n=5) 92-101% 85-94% 91-105% 83-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PSGL1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Molecular Nutrition & Food Research Endoplasmic reticulum stress contributes to ferritin molecules-mediated macrophage migrationvia P-selectin glycoprotein ligand-1. pubmed:27813270
parasite immunology The intestinal nematode inhibits T‐cell reactivity by targeting P‐GP activity pubmed:29063624
Scientific Reports Adhesion of Toxoplasma gondii tachyzoite-infected vehicle leukocytes to capillary endothelial cells triggers timely parasite egression pubmed:28720868
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA985Mu02 Recombinant P-Selectin Glycoprotein Ligand 1 (PSGL1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA985Mu01 Recombinant P-Selectin Glycoprotein Ligand 1 (PSGL1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA985Mu02 Polyclonal Antibody to P-Selectin Glycoprotein Ligand 1 (PSGL1) WB; IHC; ICC; IP.
PAA985Mu01 Polyclonal Antibody to P-Selectin Glycoprotein Ligand 1 (PSGL1) WB; IHC; ICC; IP.
SEA985Mu ELISA Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA985Mu Magnetic Luminex Assay Kit for P-Selectin Glycoprotein Ligand 1 (PSGL1) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기