제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LME330Hu

Magnetic Luminex Assay Kit for Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc.

Magnetic Luminex Assay Kit for Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc.

Detection range
Size
Sensitivity

Product No.

LME330Hu

Organism Species

Homo sapiens (Human).

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.04-40ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.013 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc..
No significant cross-reactivity or interference between Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 92-101 96
heparin plasma(n=5) 81-96 92
sodium citrate plasma(n=5) 79-89 78

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-90% 78-88% 97-105% 78-104%
EDTA plasma(n=5) 89-98% 82-97% 93-101% 85-93%
heparin plasma(n=5) 83-104% 82-95% 79-101% 79-91%
sodium citrate plasma(n=5) 86-101% 84-104% 94-103% 81-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ARHGDIb) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Clinical Proteomics Plasma Proteomics Analysis for Screening Anlotinib Responders in Non-small Cell Lung Cancer
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPE330Hu01 Recombinant Rho GDP Dissociation Inhibitor Beta (ARHGDIb) Positive Control; Immunogen; SDS-PAGE; WB.
PAE330Hu01 Polyclonal Antibody to Rho GDP Dissociation Inhibitor Beta (ARHGDIb) WB; IHC; ICC; IP.
MAE330Hu21 Monoclonal Antibody to Rho GDP Dissociation Inhibitor Beta (ARHGDIb) WB; IHC; ICC; IP.
SEE330Hu ELISA Kit for Rho GDP Dissociation Inhibitor Beta (ARHGDIb) Enzyme-linked immunosorbent assay for Antigen Detection.
LME330Hu Magnetic Luminex Assay Kit for Rho GDP Dissociation Inhibitor Beta (ARHGDIb) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기