Magnetic Luminex Assay Kit for Thyroid Peroxidase (TPO) ,etc.

Magnetic Luminex Assay Kit for Thyroid Peroxidase (TPO) ,etc.

Detection range
Size
Sensitivity

Product No.

LMA557Hu

Organism Species

Homo sapiens (Human).

Sample Type

Tissue homogenates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.02-20ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.007 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Thyroid Peroxidase (TPO) ,etc..
No significant cross-reactivity or interference between Thyroid Peroxidase (TPO) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Thyroid Peroxidase (TPO) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Thyroid Peroxidase (TPO) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-93 88
EDTA plasma(n=5) 80-101 96
heparin plasma(n=5) 89-97 92

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thyroid Peroxidase (TPO) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thyroid Peroxidase (TPO) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thyroid Peroxidase (TPO) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-105% 82-95% 91-98% 95-102%
EDTA plasma(n=5) 79-95% 79-101% 85-103% 99-105%
heparin plasma(n=5) 86-94% 86-98% 83-102% 89-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TPO) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Frontiers in cellular neuroscience Elevated Thyroid Peroxidase Antibody Increases Risk of Post-partum Depression by Decreasing Prefrontal Cortex BDNF and 5-HT Levels in Mice pubmed:28119573
Journal of Hematology & Oncology The first-in-class alkylating deacetylase inhibitor molecule tinostamustine shows antitumor effects and is synergistic with radiotherapy in preclinical models of … Pubmed:29486795
Int J Clin Pract Altered Sperm Parameters and Subclinical hypothyroidism; a cross sectional study in Karachi, Pakistan Pubmed: 32453880
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA557Hu01 Recombinant Thyroid Peroxidase (TPO) Positive Control; Immunogen; SDS-PAGE; WB.
PAA557Hu01 Polyclonal Antibody to Thyroid Peroxidase (TPO) WB; IHC; ICC; IP.
MAA557Hu22 Monoclonal Antibody to Thyroid Peroxidase (TPO) WB; IHC; ICC; IP.
SEA557Hu ELISA Kit for Thyroid Peroxidase (TPO) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA557Hu Magnetic Luminex Assay Kit for Thyroid Peroxidase (TPO) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기