SKU(재고 관리 코드):LMP196Hu

Magnetic Luminex Assay Kit for A Disintegrin And Metalloprotease 33 (ADAM33) ,etc.

Magnetic Luminex Assay Kit for A Disintegrin And Metalloprotease 33 (ADAM33) ,etc.

Detection range
Size
Sensitivity

Product No.

LMP196Hu

Organism Species

Homo sapiens (Human).

Sample Type

tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of A Disintegrin And Metalloprotease 33 (ADAM33) ,etc..
No significant cross-reactivity or interference between A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-101 95
EDTA plasma(n=5) 96-103 101
heparin plasma(n=5) 99-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 99-105% 98-105% 83-93% 88-101%
EDTA plasma(n=5) 93-101% 97-104% 93-101% 92-101%
heparin plasma(n=5) 89-104% 89-96% 90-104% 89-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ADAM33) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Clinical and Experimental Allergy The relationship of airway structural changes to blood and bronchoalveolar lavage biomarkers, and lung function abnormalities in asthma Pubmed: 31532863
journal of investigational allergology and clinical immunology Endothelial dysfunction and pentraxin-3 in clinically stable adult asthma patients Pubmed: 32376513
International Journal of Molecular Sciences Reticular Basement Membrane Thickness Is Associated with Growth-and Fibrosis-Promoting Airway Transcriptome Profile-Study in Asthma Patients 33498209
Integration of Airway In
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPP196Hu01 Recombinant A Disintegrin And Metalloprotease 33 (ADAM33) Positive Control; Immunogen; SDS-PAGE; WB.
PAP196Hu01 Polyclonal Antibody to A Disintegrin And Metalloprotease 33 (ADAM33) WB; IHC; ICC; IP.
MAP196Hu21 Monoclonal Antibody to A Disintegrin And Metalloprotease 33 (ADAM33) WB; IHC; ICC; IP.
SEP196Hu ELISA Kit for A Disintegrin And Metalloprotease 33 (ADAM33) Enzyme-linked immunosorbent assay for Antigen Detection.
LMP196Hu Magnetic Luminex Assay Kit for A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기