제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMC262Mu

Magnetic Luminex Assay Kit for Tight Junction Protein 1 (TJP1) ,etc.

Magnetic Luminex Assay Kit for Tight Junction Protein 1 (TJP1) ,etc.

Detection range
Size
Sensitivity

Product No.

LMC262Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Tight Junction Protein 1 (TJP1) ,etc..
No significant cross-reactivity or interference between Tight Junction Protein 1 (TJP1) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Tight Junction Protein 1 (TJP1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Tight Junction Protein 1 (TJP1) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 102
EDTA plasma(n=5) 80-88 84
heparin plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tight Junction Protein 1 (TJP1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tight Junction Protein 1 (TJP1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tight Junction Protein 1 (TJP1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-95% 80-101% 97-105% 99-105%
EDTA plasma(n=5) 93-105% 86-101% 97-105% 92-101%
heparin plasma(n=5) 84-97% 91-101% 81-103% 96-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:TJP1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Current Nutrition & Food Science Barrier Strengthening and Anti-inflammatory Effect of Cucurbit Fruits on Intestinal Epithelial Cells In-vitro 10.2174:1573401313666170427123153
Journal of Translational Medicine Gut microbiota from coronary artery disease patients contributes to vascular dysfunction in mice by regulating bile acid metabolism and immune activation Pubmed: 33036625
Neural Regeneration Research Inhibition of nitric oxide synthase aggravates brain injury in diabetic rats with traumatic brain injury 33433486
PLoS One A comparison of the effects of monotherapy with rosuvastatin, atorvastatin or ezetimibe versus combination treatment with rosuvastatin-ezetimibe and … 34492054
J Agric Food Chem Pyocyanin Modulates Gastrointestinal Transformation and Microbiota Pubmed:35171599
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
SEC262Mu ELISA Kit for Tight Junction Protein 1 (TJP1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC262Mu Magnetic Luminex Assay Kit for Tight Junction Protein 1 (TJP1) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기