SKU(재고 관리 코드):LMB139Mu
Magnetic Luminex Assay Kit for Antidiuretic Hormone (ADH) ,etc.
Magnetic Luminex Assay Kit for Antidiuretic Hormone (ADH) ,etc.
Product No.
LMB139Mu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Competitive Inhibition
Assay Length
1.5h
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Antidiuretic Hormone (ADH) ,etc..
No significant cross-reactivity or interference between Antidiuretic Hormone (ADH) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Antidiuretic Hormone (ADH) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Antidiuretic Hormone (ADH) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-103 | 85 |
EDTA plasma(n=5) | 93-101 | 97 |
heparin plasma(n=5) | 93-105 | 97 |
sodium citrate plasma(n=5) | 78-102 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Antidiuretic Hormone (ADH) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Antidiuretic Hormone (ADH) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Antidiuretic Hormone (ADH) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 92-101% | 81-104% | 94-102% | 91-98% |
EDTA plasma(n=5) | 82-96% | 80-104% | 85-103% | 81-97% |
heparin plasma(n=5) | 95-102% | 78-92% | 87-104% | 79-99% |
sodium citrate plasma(n=5) | 83-92% | 85-96% | 96-103% | 85-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:ADH) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Neuroscience | Angiotensin II Type 1a Receptors in the Subfornical Organ Modulate Neuroinflammation in the Hypothalamic Paraventricular Nucleus in Heart Failure Rats Pubmed:29684507 |
American Journal of Physiology-Renal Physiology | Chronic nicotine exposure reduces klotho expression and triggers different renal and hemodynamic responses in -haploinsufficient mice Pubmed:29363324 |
The Eurasian Journal of Medicine | Effects of Conivaptan versus Mannitol on Post-Ischemic Brain Injury and Edema |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
CEB139Mu | ELISA Kit for Antidiuretic Hormone (ADH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCB139Mu | CLIA Kit for Antidiuretic Hormone (ADH) | Chemiluminescent immunoassay for Antigen Detection. |
LMB139Mu | Magnetic Luminex Assay Kit for Antidiuretic Hormone (ADH) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSB139Mu11 | ELISA Kit DIY Materials for Antidiuretic Hormone (ADH) | Main materials for "Do It (ELISA Kit) Yourself". |