제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMF822Ra

Magnetic Luminex Assay Kit for Phosphatase And Tensin Homolog (PTEN) ,etc.

Magnetic Luminex Assay Kit for Phosphatase And Tensin Homolog (PTEN) ,etc.

Detection range
Size
Sensitivity

Product No.

LMF822Ra

Organism Species

Rattus norvegicus (Rat).

Sample Type

Tissue homogenates, cell lysates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.01-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.003 ng/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Phosphatase And Tensin Homolog (PTEN) ,etc..
No significant cross-reactivity or interference between Phosphatase And Tensin Homolog (PTEN) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Phosphatase And Tensin Homolog (PTEN) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Phosphatase And Tensin Homolog (PTEN) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-101 93
EDTA plasma(n=5) 81-88 85
heparin plasma(n=5) 79-93 84
sodium citrate plasma(n=5) 95-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phosphatase And Tensin Homolog (PTEN) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phosphatase And Tensin Homolog (PTEN) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phosphatase And Tensin Homolog (PTEN) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-104% 97-105% 83-96% 92-105%
EDTA plasma(n=5) 87-94% 99-105% 78-101% 91-99%
heparin plasma(n=5) 79-98% 97-105% 97-105% 81-102%
sodium citrate plasma(n=5) 92-101% 92-105% 96-103% 93-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PTEN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Experimental and Therapeutic Medicine Elucidating the mechanism of miRNA‑214 in the regulation of gingival carcinoma 10.3892/etm.2017.4264
Cancers (Basel) In Vivo and In Vitro Enhanced Tumoricidal Effects of Metformin, Active Vitamin D3, and 5-Fluorouracil Triple Therapy against Colon Cancer by Modulating the … Pubmed:35326689
Metformin and Calcitriol Enhance 5-Fluorouracil Tumoricidal Effects in Colon Cancer By Modulating The PI3K/Akt/PTEN/mTOR Network
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPF822Ra01 Recombinant Phosphatase And Tensin Homolog (PTEN) Positive Control; Immunogen; SDS-PAGE; WB.
PAF822Ra01 Polyclonal Antibody to Phosphatase And Tensin Homolog (PTEN) WB; IHC; ICC; IP.
MAF822Ra21 Monoclonal Antibody to Phosphatase And Tensin Homolog (PTEN) WB; IHC; ICC; IP.
SEF822Ra ELISA Kit for Phosphatase And Tensin Homolog (PTEN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMF822Ra Magnetic Luminex Assay Kit for Phosphatase And Tensin Homolog (PTEN) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기