SKU(재고 관리 코드):LMA971Hu
Magnetic Luminex Assay Kit for Glypican 3 (GPC3) ,etc.
Magnetic Luminex Assay Kit for Glypican 3 (GPC3) ,etc.
Product No.
LMA971Hu
Organism Species
Homo sapiens (Human).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3.5h
Detection Range
0.01-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.003 ng/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Glypican 3 (GPC3) ,etc..
No significant cross-reactivity or interference between Glypican 3 (GPC3) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glypican 3 (GPC3) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Glypican 3 (GPC3) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 82-96 | 91 |
EDTA plasma(n=5) | 84-92 | 88 |
heparin plasma(n=5) | 86-94 | 89 |
sodium citrate plasma(n=5) | 97-105 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glypican 3 (GPC3) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glypican 3 (GPC3) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glypican 3 (GPC3) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-94% | 83-104% | 95-104% | 99-105% |
EDTA plasma(n=5) | 87-101% | 82-94% | 83-96% | 92-101% |
heparin plasma(n=5) | 91-102% | 97-105% | 95-103% | 96-105% |
sodium citrate plasma(n=5) | 80-89% | 84-92% | 89-98% | 91-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:GPC3) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
Nature and Science | Diagnostic Role of Serum Glypican-3 as a Tumor Marker for Hepatocellular Carcinoma Sciencepub:10043238 |
Journal of Applied Pharmaceutical Science | Cytotoxic effects of antiglypican-3 against HepG2 cell line Ebscohost: Source |
Asian Pacific Journal of Cancer Prevention | Can Glypican3 be Diagnostic for Early Hepatocellular Carcinoma among Egyptian Patients? Pubmed: 24460300 |
Clin Biochem. | Diagnostic accuracy of serum glypican-3 for hepatocellular carcinoma: A systematic review and meta-analysis Pubmed: 24362268 |
Science and Nature | Diagnostic Role of Serum Glypican-3 as Hepatocellular Carcinoma Zolcat: Source |
Alexandria Journal of Medicine | Role of serum glypican-3 in the diagnosis and differentiation of small hepatocellular carcinoma from hepatitis-C virus cirrhosis ScienceDirect: S2090506814000062 |
J Egypt Natl Canc Inst. | Comparing prothrombin induced by vitamin K absence-II (PIVKA-II) with the oncofetal proteins glypican-3, Alpha feto protein and carcinoembryonic antigen in diagnosing hepatocellular carcinoma among Egyptian patients. Pubmed:24841158 |
European Journal of Pharmacology | Evaluation of antiglypican-3 therapy as a promising target for amelioration of hepatic tissue damage in hepatocellular carcinoma Pubmed:25449037 |
Hepatobiliary Pancreat Dis Int | Predictive value of tumor markers in patients with recurrent hepatocellular carcinoma in different vascular invasion pattern abstract:abstract4525.shtml |
Clinical and Molecular Hepatology | Glypican-3 level assessed by the enzyme-linked immunosorbent assay is inferior to alpha-fetoprotein level for hepatocellular carcinoma diagnosis pmc:articles |
Wiley | Glypican‐3: A promising biomarker for hepatocellular carcinoma diagnosis and treatment pubmed:28621802 |
Biomedicine & Pharmacotherapy | Cytotoxic and partial hepatoprotective activity of sodium ascorbate against hepatocellular carcinoma through inhibition of sulfatase-2 and Pubmed:29669302 |
Journal of Cancer and Clinical Oncology | Development and Validation of a Two-Site Immunoradiometric assay for Glypican-3 in plasma: Implication in Diagnosis of Hepatocellular Carcinoma Researchgate:Source |
Turkish journal of oncology | Serum Glypican-3, Vascular Endothelial Growth Factor, and Interleukin-6 Levels in Hepatocellular Carcinoma 10.5505:tjo.2018.1742 |
Intensive Care Medicine Experimental | Elevated plasma glypicans are associated with organ failure in patients with infection Pubmed: 30618011 |
VALUE OF SERUM GLYPICAN 3 AS A PREDICTIVE TOOL FOR EARLY DIAGNOSIS OF HEPATOCELLULAR CARCINOMA (HCC) | |
ADVANCED RESEARCHES | Search for Effective Serum Tumor Markers for Early Diagnosis of Hepatocellular Carcinoma Associated with Hepatitis C |
Life Sci | Selenium nanoparticles overcomes sorafenib resistance in thioacetamide induced hepatocellular carcinoma in rats by modulation of mTOR, NF-κB pathways and … Pubmed:35640776 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPA971Hu02 | Recombinant Glypican 3 (GPC3) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA971Hu01 | Recombinant Glypican 3 (GPC3) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA971Hu01 | Polyclonal Antibody to Glypican 3 (GPC3) | WB; ICC; IHC-P; IHC-F; ELISA. |
MAA971Hu21 | Monoclonal Antibody to Glypican 3 (GPC3) | WB; IHC; ICC; IP. |
MAA971Hu22 | Monoclonal Antibody to Glypican 3 (GPC3) | WB; IHC; ICC; IP. |
MAA971Hu24 | Monoclonal Antibody to Glypican 3 (GPC3) | WB; IHC; ICC; IP. |
MAA971Hu23 | Monoclonal Antibody to Glypican 3 (GPC3) | WB; IHC; ICC; IP. |
MAA971Hu25 | Monoclonal Antibody to Glypican 3 (GPC3) | WB; IHC; ICC; IP. |
SEA971Hu | ELISA Kit for Glypican 3 (GPC3) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA971Hu | Magnetic Luminex Assay Kit for Glypican 3 (GPC3) ,etc. | Magnetic Luminex Assay for Antigen Detection. |