제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMC288Mu

Magnetic Luminex Assay Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc.

Magnetic Luminex Assay Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc.

Detection range
Size
Sensitivity

Product No.

LMC288Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Serum, plasma, tissue homogenates, cell lysates and other biological fluids.

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.98-1000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.327 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex


    Specificity

    This assay has high sensitivity and excellent specificity for detection of Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc..
    No significant cross-reactivity or interference between Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. and analogues was observed.

    Recovery

    Matrices listed below were spiked with certain level of recombinant Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. in samples.

    Matrix Recovery range (%) Average(%)
    serum(n=5) 98-105 101
    EDTA plasma(n=5) 91-99 95
    heparin plasma(n=5) 82-95 86

    Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Linearity

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

    Sample 1:2 1:4 1:8 1:16
    serum(n=5) 86-104% 86-94% 80-98% 79-96%
    EDTA plasma(n=5) 88-103% 90-104% 81-90% 99-105%
    heparin plasma(n=5) 82-95% 93-101% 91-98% 80-99%

    Stability

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Reagents and materials provided

    Reagents Quantity Reagents Quantity
    96-well plate 1 Plate sealer for 96 wells 4
    Pre-Mixed Standard 2 Standard Diluent 1×20mL
    Pre-Mixed Magnetic beads (22#:IBA1) 1 Analysis buffer 1×20mL
    Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
    Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
    Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
    Instruction manual 1

    Assay procedure summary

    1. Preparation of standards, reagents and samples before the experiment;
    2. Add 100μL standard or sample to each well,
        add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
    3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
    4. Wash plate on magnetic frame for three times;
    5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
    6. Wash plate on magnetic frame for three times;
    7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

    Magazine Citations
    Biosci Trends. Allograft inflammatory factor-1 in the pathogenesis of bleomycin-induced acute lung injury Pubmed:26911661
    Cardiovasc Pathol A novel role for the Krüppel-like factor 14 on macrophage inflammatory response and atherosclerosis development pubmed:27923151
    IOS Press Content Library An Intranasal Formulation of Erythropoietin (Neuro-EPO) Prevents Memory Deficits and Amyloid Toxicity in the APPSwe Transgenic Mouse Model of Alzheimer's … articles:journal-of-alzheimers-disease
    博士论文 INSTITUTO DE CIENCIAS BÁSICAS Y PRECLÍNICAS “VICTORIA DE GIRÓN” DEPARTAMENTO DE HISTOLOGÍA
    Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
    RPC288Mu01 Recombinant Ionized Calcium-binding Adapter Molecule 1 (IBA1) Positive Control; Immunogen; SDS-PAGE; WB.
    RPC288Mu02 Recombinant Ionized Calcium-binding Adapter Molecule 1 (IBA1) Positive Control; Immunogen; SDS-PAGE; WB.
    PAC288Mu02 Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
    PAC288Mu01 Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC; IP.
    LAC288Mu71 Biotin-Linked Polyclonal Antibody to Ionized Calcium-binding Adapter Molecule 1 (IBA1) WB; IHC; ICC.
    SEC288Mu ELISA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Enzyme-linked immunosorbent assay for Antigen Detection.
    SCC288Mu CLIA Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) Chemiluminescent immunoassay for Antigen Detection.
    LMC288Mu Magnetic Luminex Assay Kit for Ionized Calcium-binding Adapter Molecule 1 (IBA1) ,etc. Magnetic Luminex Assay for Antigen Detection.
    전체 세부 정보 보기