제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB934Mu

Magnetic Luminex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc.

Magnetic Luminex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB934Mu

Organism Species

Mus musculus (Mouse).

Sample Type

serum, plasma and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3.5h

Detection Range

0.98-1000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.327 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

Specificity

This assay has high sensitivity and excellent specificity for detection of Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc..
No significant cross-reactivity or interference between Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-101 92
EDTA plasma(n=5) 97-105 101
heparin plasma(n=5) 90-98 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 81-93% 91-99% 81-93%
EDTA plasma(n=5) 78-94% 78-97% 82-99% 80-93%
heparin plasma(n=5) 95-103% 92-105% 85-99% 95-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LRG1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

 

Magazine Citations
Clin Exp Nephrol Differentially expressed urinary biomarkers in children with idiopathic nephrotic syndrome PubMed: 26351173
Journal of Proteome Research Targeted proteomics predict a sustained complete-response after transarterial chemoembolization and clinical outcomes in patients with hepatocellular carcinoma: a prospective cohort study pubmed:28112944
OncoTargets and Therapy leucine-rich alpha-2-glycoprotein-1 is up-regulated in colorectal cancer and is a tumor promoter Pubmed:29785123
PROTEOMICS – Clinical Applications Screening and Identification of Pregnancy Zone Protein (PZP) and Leucine‐Rich Alpha‐2‐Glycoprotein (LRG) as Potential Serum Biomarkers for Early‐onset … Pubmed: 30411527
Cancer Management and Research iTRAQ-based quantitative protein expression profiling of biomarkers in childhood B-cell and T-cell acute lymphoblastic leukemia Pubmed: 31440093
J Clin Med A Three-Protein Panel to Support the Diagnosis of Sepsis in Children Pubmed:35329889
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB934Mu02 Recombinant Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) Positive Control; Immunogen; SDS-PAGE; WB.
RPB934Mu03 Recombinant Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) Positive Control; Immunogen; SDS-PAGE; WB.
RPB934Mu01 Recombinant Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB934Mu01 Polyclonal Antibody to Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) WB; IHC; ICC; IP.
PAB934Mu03 Polyclonal Antibody to Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) WB; IHC; ICC; IP.
PAB934Mu02 Polyclonal Antibody to Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) WB; IHC; ICC; IP.
SEB934Mu ELISA Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB934Mu Magnetic Luminex Assay Kit for Leucine Rich Alpha-2-Glycoprotein 1 (LRG1) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기