SKU(재고 관리 코드):LMA858Ge
Magnetic Luminex Assay Kit for Epinephrine (EPI) ,etc.
Magnetic Luminex Assay Kit for Epinephrine (EPI) ,etc.
Product No.
LMA858Ge
Organism Species
Pan-species (General).
Sample Type
serum, plasma, cell lysates, cell culture supernates and other biological fluids
Test Method
Competitive Inhibition
Assay Length
1.5h
Detection Range
1.95-2000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.65 pg/mL.
UOM
1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex
Specificity
This assay has high sensitivity and excellent specificity for detection of Epinephrine (EPI) ,etc..
No significant cross-reactivity or interference between Epinephrine (EPI) ,etc. and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Epinephrine (EPI) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Epinephrine (EPI) ,etc. in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-102 | 94 |
EDTA plasma(n=5) | 93-101 | 96 |
heparin plasma(n=5) | 89-96 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Epinephrine (EPI) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Epinephrine (EPI) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Epinephrine (EPI) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 87-97% | 80-96% | 91-99% | 83-95% |
EDTA plasma(n=5) | 85-105% | 98-105% | 88-101% | 90-97% |
heparin plasma(n=5) | 78-95% | 79-91% | 78-94% | 90-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:EPI) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Magazine | Citations |
European Patent Application EP2371376 | METHODS AND REAGENTS FOR THE DIAGNOSIS, PREVENTION AND TREATMENT OF INSULIN RESISTANCE FPO:EO237136 |
Cardiovasc Diabetol | Glibenclamide attenuates myocardial injury by lipopolysaccharides in streptozotocin-induced diabetic mice Pubmed:Pmc4147163 |
Autonomic Neuroscience | Study of baicalin on sympathoexcitation induced by myocardial ischemia via P2X3 receptor in superior cervical ganglia Pubmed:25554221 |
Neuropsychiatr Dis Treat | Catha edulis chewing effects on treatment of paranoid schizophrenic patients PubMed: 25926735 |
PLoS One | Ablation of Potassium-Chloride Cotransporter Type 3 (Kcc3) in Mouse Causes Multiple Cardiovascular Defects and Isosmotic Polyuria Pubmed:27166674 |
Scientific Reports | Reduced lipolysis response to adipose afferent reflex involved in impaired activation of adrenoceptor-cAMP-PKA-hormone sensitive lipase pathway in obesity pubmed:27694818 |
International Journal of Nursing Practice | Non‐pharmacological interventions during childbirth for pain relief, anxiety, and neuroendocrine stress parameters: A randomized controlled trial Pubmed:29512230 |
Serbian Journal of Experimental and Clinical Research | Assessment of the TDCS Influence on Stress-Induced Disorders in Rats with Low Stress Sustainability and Endurance |
Frontiers in Endocrinology | RFRP-3, the Mammalian Ortholog of GnIH, Is a Novel Modulator Involved in Food Intake and Glucose Homeostasis Pubmed: 32328034 |
Nature | Feeding induces cholesterol biosynthesis via the mTORC1–USP20–HMGCR axis Pubmed: 33177714 |
Blockade of adrenergic β‐receptor activation through local delivery of propranolol from a 3D collagen/polyvinyl alcohol/hydroxyapatite scaffold promotes bone repair … | |
Anti-stress activity of some plants extracts of the North Caucasus flora | |
Mol Metab | Adipose tissue lipolysis is regulated by PAQR11 via altering protein stability of phosphodiesterase 4D 33549845 |
CRYOBIOLOGY | O-GlcNAc/Akt pathway regulates glucose metabolism and reduces apoptosis in liver of piglets with acute cold stress 33651993 |
Hypertension | Expression of LHCGR (Luteinizing Hormone/Chorionic Gonadotrophin Receptor) in Pheochromocytomas Unveils an Endocrine Mechanism Connecting Pregnancy … Pubmed:35189708 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPA858Ge11 | BSA Conjugated Epinephrine (EPI) | Immunogen; SDS-PAGE; WB. |
CPA858Ge21 | OVA Conjugated Epinephrine (EPI) | Immunogen; SDS-PAGE; WB. |
PAA858Ge01 | Polyclonal Antibody to Epinephrine (EPI) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAA858Ge26 | Monoclonal Antibody to Epinephrine (EPI) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAA858Ge25 | Monoclonal Antibody to Epinephrine (EPI) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAA858Ge22 | Monoclonal Antibody to Epinephrine (EPI) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
CEA858Ge | ELISA Kit for Epinephrine (EPI) | Enzyme-linked immunosorbent assay for Antigen Detection. |
IEA858Ge | Instant ELISA Kit for Epinephrine (EPI) | Enzyme-linked immunosorbent assay for Antigen Detection. |
HEA858Ge | High Sensitive ELISA Kit for Epinephrine (EPI) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA858Ge | Magnetic Luminex Assay Kit for Epinephrine (EPI) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSA858Ge11 | ELISA Kit DIY Materials for Epinephrine (EPI) | Main materials for "Do It (ELISA Kit) Yourself". |