제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):LMB044Gu

Magnetic Luminex Assay Kit for Cholecystokinin 8 (CCK8) ,etc.

Magnetic Luminex Assay Kit for Cholecystokinin 8 (CCK8) ,etc.

Detection range
Size
Sensitivity

Product No.

LMB044Gu

Organism Species

Cavia (Guinea pig ).

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Competitive Inhibition

Assay Length

1.5h

Detection Range

0.98-1000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.327 pg/mL.

UOM

1Plex 2Plex 3Plex 4Plex 5Plex 6Plex 7Plex 8Plex

 

    Specificity

    This assay has high sensitivity and excellent specificity for detection of Cholecystokinin 8 (CCK8) ,etc..
    No significant cross-reactivity or interference between Cholecystokinin 8 (CCK8) ,etc. and analogues was observed.

    Recovery

    Matrices listed below were spiked with certain level of recombinant Cholecystokinin 8 (CCK8) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Cholecystokinin 8 (CCK8) ,etc. in samples.

    Matrix Recovery range (%) Average(%)
    serum(n=5) 95-103 99
    EDTA plasma(n=5) 89-96 92
    heparin plasma(n=5) 78-98 85

    Precision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cholecystokinin 8 (CCK8) ,etc. were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cholecystokinin 8 (CCK8) ,etc. were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Linearity

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cholecystokinin 8 (CCK8) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

    Sample 1:2 1:4 1:8 1:16
    serum(n=5) 79-90% 88-101% 89-101% 93-105%
    EDTA plasma(n=5) 99-105% 87-96% 88-101% 79-103%
    heparin plasma(n=5) 79-95% 78-104% 80-99% 98-105%

    Stability

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Reagents and materials provided

    Reagents Quantity Reagents Quantity
    96-well plate 1 Plate sealer for 96 wells 4
    Pre-Mixed Standard 2 Standard Diluent 1×20mL
    Pre-Mixed Magnetic beads (22#:CCK8) 1 Analysis buffer 1×20mL
    Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
    Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
    Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
    Instruction manual 1

    Assay procedure summary

    1. Preparation of standards, reagents and samples before the experiment;
    2. Add 50μL standard or sample to each well,
        add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
    3. Wash plate on magnetic frame for three times;
    4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
    5. Wash plate on magnetic frame for three times;
    6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

    Magazine Citations
    World J Gastroenterol Roles of sphincter of Oddi motility and serum vasoactive intestinal peptide, gastrin and cholecystokinin octapeptide NCBI: PMC4000510
    Epilepsy Research A prospective study on changes in blood levels of cholecystokinin-8 and leptin in patients with refractory epilepsy treated with the ketogenic diet. pubmed:27568597
    Journal of Ethnopharmacology Luhong formula inhibits myocardial fibrosis in a paracrine manner by activating thegp130/JAK2/STAT3 pathway in cardiomyocytes. pubmed:28115285
    Untersuchungen zu verschiedenen biochemischen Markern des zentralen Nervensystems im Liquor cerebrospinalis von Patienten mit der Huntington-Krankheit :
    Journal of Functional Foods The protective effect of Capparis spinosa fruit on triptolide-induced acute liver injury: A metabolomics-based systematic study
    Catalog No. Related products for research use of Cavia (Guinea pig ) Organism species Applications (RESEARCH USE ONLY!)
    CEB044Gu ELISA Kit for Cholecystokinin 8 (CCK8) Enzyme-linked immunosorbent assay for Antigen Detection.
    LMB044Gu Magnetic Luminex Assay Kit for Cholecystokinin 8 (CCK8) ,etc. Magnetic Luminex Assay for Antigen Detection.