SKU(재고 관리 코드):HEA766Mu
High Sensitive ELISA Kit for A Disintegrin And Metalloprotease 10 (ADAM10)
High Sensitive ELISA Kit for A Disintegrin And Metalloprotease 10 (ADAM10)
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
HEA766Mu
Organism Species
Mus musculus (Mouse).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
9.4-600pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 3.2pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of High Sensitive A Disintegrin And Metalloprotease 10 (ADAM10).
No significant cross-reactivity or interference between High Sensitive A Disintegrin And Metalloprotease 10 (ADAM10) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant High Sensitive A Disintegrin And Metalloprotease 10 (ADAM10) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive A Disintegrin And Metalloprotease 10 (ADAM10) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 96-104 | 101 |
EDTA plasma(n=5) | 82-89 | 86 |
heparin plasma(n=5) | 92-101 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive A Disintegrin And Metalloprotease 10 (ADAM10) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive A Disintegrin And Metalloprotease 10 (ADAM10) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive A Disintegrin And Metalloprotease 10 (ADAM10) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-97% | 81-88% | 95-102% | 87-102% |
EDTA plasma(n=5) | 80-95% | 95-105% | 80-95% | 96-103% |
heparin plasma(n=5) | 84-94% | 91-105% | 81-94% | 79-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Magazine | Citations |
Journal of Allergy and Clinical Immunology | RAGE processing in chronic airway conditions: Involvement of Staphylococcus aureus and ECP ScienceDirect: S0091674912003508 |
British journal of cancer | ADAM10: a new player in breast cancer progression? PubMed: 26284334 |
Int Wound J. | From varices to venous ulceration: the story of chronic venous disease described by metalloproteinases. Pubmed:26991748 |
International Wound Journal | From varices to venous ulceration: the story of chronic venous disease described by metalloproteinases pubmed:26991748 |
Disease Markers | Adamalysines as Biomarkers and a Potential Target of Therapy in Colorectal Cancer Patients: Preliminary Results Pubmed: 31565100 |
ADAM10 Plasma Levels Predict Worsening in Cognition of Older Adults: A 3-Year Follow-Up Study | |
Alzheimers Research & Therapy | ADAM10 plasma levels predict worsening in cognition of older adults: a 3-year follow-up study. 33419480 |
life | High Levels of TNF-¦Á and TIM-3 as a Biomarker of Immune Reconstitution Inflammatory Syndrome in People with HIV Infection |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA766Mu01 | Recombinant A Disintegrin And Metalloprotease 10 (ADAM10) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA766Mu02 | Recombinant A Disintegrin And Metalloprotease 10 (ADAM10) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA766Mu01 | Polyclonal Antibody to A Disintegrin And Metalloprotease 10 (ADAM10) | WB; IHC; ICC; IP. |
PAA766Mu02 | Polyclonal Antibody to A Disintegrin And Metalloprotease 10 (ADAM10) | WB; IHC; ICC; IP. |
HEA766Mu | High Sensitive ELISA Kit for A Disintegrin And Metalloprotease 10 (ADAM10) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEA766Mu | ELISA Kit for A Disintegrin And Metalloprotease 10 (ADAM10) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA766Mu | Magnetic Luminex Assay Kit for A Disintegrin And Metalloprotease 10 (ADAM10) ,etc. | Magnetic Luminex Assay for Antigen Detection. |