SKU(재고 관리 코드):HEA726Po
High Sensitive ELISA Kit for Prealbumin (PALB)
High Sensitive ELISA Kit for Prealbumin (PALB)
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
HEA726Po
Organism Species
Sus scrofa; Porcine (Pig).
Sample Type
serum, plasma and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
78-5000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 25pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of High Sensitive Prealbumin (PALB).
No significant cross-reactivity or interference between High Sensitive Prealbumin (PALB) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant High Sensitive Prealbumin (PALB) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Prealbumin (PALB) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 81-101 | 93 |
EDTA plasma(n=5) | 80-105 | 101 |
heparin plasma(n=5) | 89-97 | 93 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Prealbumin (PALB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Prealbumin (PALB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Prealbumin (PALB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-88% | 90-104% | 99-105% | 87-103% |
EDTA plasma(n=5) | 83-105% | 78-93% | 82-91% | 84-95% |
heparin plasma(n=5) | 89-104% | 78-97% | 82-98% | 81-89% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Magazine | Citations |
Chinese Medical Journal | Screening disease-associated proteins from sera of patients with rheumatoid arthritis: a comparative proteomic study PubMed: 20367977 |
Journal of Vascular Surgery | Circulation levels of acute phase proteins in patients with Takayasu arteritis PubMed: 20100644 |
Journal of Pharmaceutical and Biomedical Analysis | Effect of high dose thiamine on the levels of urinary protein biomarkers in diabetes mellitus type 2 PubMed: 21130593 |
Toxicology Letters | Serum proteomic analysis reveals potential serum biomarkers for occupational medicamentosa-like dermatitis caused by trichloroethylene Pubmed:24960064 |
Journal of Neurochemistry | Schwann cells contribute to neurodegeneration in transthyretin amyloidosis Pubmed:25693163 |
Anal Biochem | Surface plasmon resonance assay of inhibition by pharmaceuticals for thyroxine hormone binging to transport proteins PubMed: 26384643 |
United States Patent Application | Compositions and Methods for Diagnosing Lung Cancer y2016:0077095.html |
Neurotherapeutics | iTRAQ-Based Quantitative Proteomics Reveals the New Evidence Base for Traumatic Brain Injury Treated with Targeted Temperature Management pubmed:29247448 |
Neuroimmunomodulation | CD4+ T Cells Affect the Thyroid Hormone Transport at the Choroid Plexus in Mice Raised in Enriched Environment Pubmed: 30703773 |
Diagnostics | Systemic Alterations of Immune Response-Related Proteins during Glaucoma Development in the Murine Model DBA/2J Pubmed: 32585848 |
Circulation-Genomic and Precision Medicine | Primary Cardiac Involvement in the Rare Transthyretin Ile73Val Mutation: A Case Series Pubmed: 32393063 |
Catalog No. | Related products for research use of Sus scrofa; Porcine (Pig) Organism species | Applications (RESEARCH USE ONLY!) |
RPA726Po01 | Recombinant Prealbumin (PALB) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA726Po01 | Polyclonal Antibody to Prealbumin (PALB) | WB; IHC; ICC; IP. |
MAA726Po21 | Monoclonal Antibody to Prealbumin (PALB) | WB; IHC; ICC; IP. |
SEA726Po | ELISA Kit for Prealbumin (PALB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
HEA726Po | High Sensitive ELISA Kit for Prealbumin (PALB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA726Po | Magnetic Luminex Assay Kit for Prealbumin (PALB) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSA726Po01 | ELISA Kit DIY Materials for Prealbumin (PALB) | Main materials for "Do It (ELISA Kit) Yourself". |