제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):SEB555Mu

ELISA Kit for A Disintegrin And Metalloprotease 17 (ADAM17)

ELISA Kit for A Disintegrin And Metalloprotease 17 (ADAM17)

UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEB555Mu

Organism Species

Mus musculus (Mouse).

Sample Type

Tissue homogenates, cell lysates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

0.156-10ng/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 0.057ng/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

 

Specificity

This assay has high sensitivity and excellent specificity for detection of A Disintegrin And Metalloprotease 17 (ADAM17).
No significant cross-reactivity or interference between A Disintegrin And Metalloprotease 17 (ADAM17) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level A Disintegrin And Metalloprotease 17 (ADAM17) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level A Disintegrin And Metalloprotease 17 (ADAM17) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
Int Wound J. From varices to venous ulceration: the story of chronic venous disease described by metalloproteinases. Pubmed:26991748
International Wound Journal From varices to venous ulceration: the story of chronic venous disease described by metalloproteinases pubmed:26991748
Biomedical Research ADAM17 regulates TNF-α expression upon lipopolysaccharide stimulation in oral keratinocytes. pubmed:28637950
Cytometry B Clin Cytom L‐Selectin Expression Is Influenced by Phosphatase Activity in Chronic Lymphocytic Leukemia Pubmed: 30729673
Disease Markers Adamalysines as Biomarkers and a Potential Target of Therapy in Colorectal Cancer Patients: Preliminary Results Pubmed: 31565100
Chem Biol Interact PEG-SOD attenuates the mitogenic ERK1/2 signaling cascade induced by cyclosporin A in the liver and kidney of albino mice Pubmed: 32866465
life High Levels of TNF-¦Á and TIM-3 as a Biomarker of Immune Reconstitution Inflammatory Syndrome in People with HIV Infection
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
SEB555Mu ELISA Kit for A Disintegrin And Metalloprotease 17 (ADAM17) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB555Mu Magnetic Luminex Assay Kit for A Disintegrin And Metalloprotease 17 (ADAM17) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기