제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):IEA877Ge

Instant ELISA Kit for Thromboxane B2 (TXB2)

Instant ELISA Kit for Thromboxane B2 (TXB2)

UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

IEA877Ge

Organism Species

Pan-species (General).

Sample Type

Serum, plasma and other biological fluids

Test Method

Competitive Inhibition

Assay Length

1h, 10min

Detection Range

18.52-1,500pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 7.14pg/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Instant Thromboxane B2 (TXB2).
No significant cross-reactivity or interference between Instant Thromboxane B2 (TXB2) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Instant Thromboxane B2 (TXB2) and the recovery rates were calculated by comparing the measured value to the expected amount of Instant Thromboxane B2 (TXB2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-105 101
EDTA plasma(n=5) 78-103 90
heparin plasma(n=5) 79-101 83

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Thromboxane B2 (TXB2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Thromboxane B2 (TXB2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Instant Thromboxane B2 (TXB2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-105% 80-101% 85-98% 94-105%
EDTA plasma(n=5) 93-101% 87-95% 85-92% 89-96%
heparin plasma(n=5) 85-103% 89-99% 80-101% 90-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 5 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Share and mix. Incubate 50 minutes at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 10 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
Available at SSRN 3335365  Evaluating the Platelet Activation Related to the Degradation of Biomaterials by Scheme of Molecular Markers
journal of thoracic and cardiovascular surgery Evaluating Platelet Activation Related to the Degradation of Biomaterials Using Molecular Markers Pubmed: 32812629
Thrombosis Research Feasibility study of use of rabbit blood to evaluate platelet activation by medical devices Pubmed: 31838449
blood advances The binding of autotaxin to integrins mediates hyperhomocysteinemia-potentiated platelet activation and thrombosis 34559203
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
CPA877Ge11 BSA Conjugated Thromboxane B2 (TXB2) Immunogen; SDS-PAGE; WB.
MAA877Ge23 Monoclonal Antibody to Thromboxane B2 (TXB2) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA877Ge21 Monoclonal Antibody to Thromboxane B2 (TXB2) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA877Ge22 Monoclonal Antibody to Thromboxane B2 (TXB2) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
CEA877Ge ELISA Kit for Thromboxane B2 (TXB2) Enzyme-linked immunosorbent assay for Antigen Detection.
IEA877Ge Instant ELISA Kit for Thromboxane B2 (TXB2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA877Ge Magnetic Luminex Assay Kit for Thromboxane B2 (TXB2) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기