제품 정보로 건너뛰기
1 1

Cloud-clone

SKU(재고 관리 코드):SEA760Hu

ELISA Kit for Inhibin B (INHB)

ELISA Kit for Inhibin B (INHB)

UOM
Sensitivity
Detection range

Enzyme-linked immunosorbent assay for Antigen Detection.

Product No.

SEA760Hu

Organism Species

Homo sapiens (Human).

Sample Type

serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Test Method

Double-antibody Sandwich

Assay Length

3h

Detection Range

15.6-1,000pg/mL

Sensitivity

The minimum detectable dose of this kit is typically less than 5.5pg/mL.

UOM

48T 96T 96T*5 96T*10 96T*100

 

Specificity

This assay has high sensitivity and excellent specificity for detection of Inhibin B (INHB).
No significant cross-reactivity or interference between Inhibin B (INHB) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Inhibin B (INHB) and the recovery rates were calculated by comparing the measured value to the expected amount of Inhibin B (INHB) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 92-105 96
heparin plasma(n=5) 83-91 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibin B (INHB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibin B (INHB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inhibin B (INHB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 80-94% 93-102% 89-103%
EDTA plasma(n=5) 91-101% 80-92% 90-105% 84-98%
heparin plasma(n=5) 86-95% 96-105% 79-92% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Magazine Citations
Adv Med Sci. Are anti-MĂźllerian hormone and its receptor polymorphism associated with the hormonal condition of undescended testes? Pubmed:27162065
Chemosphere. Gestational and lactational exposure to bisphenol AF in maternal rats increases testosterone levels in 23-day-old male offspring. pubmed:27567155
PLoS One Overexpression of ubiquitin carboxyl-terminal hydrolase 1 (UCHL1) in boys with cryptorchidism Pubmed:29401475
Journal of Ovarian Research Comparison of the influence of three fibroid treatment options: supracervical hysterectomy, ulipristal acetate and uterine artery embolization on ovarian … Pubmed:29859107
Stem Cell Research & Therapy Endometrial mesenchymal stem cells isolated from menstrual blood repaired epirubicin-induced damage to human ovarian granulosa cells by inhibiting the … Pubmed: 30606243
Endocrinology Diabetes Type 1 Negatively Influences Leydig Cell Function in Rats, Which is Partially Reversible By Insulin Treatment 33507237
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA760Hu01 Recombinant Inhibin B (INHB) Positive Control; Immunogen; SDS-PAGE; WB.
SEA760Hu ELISA Kit for Inhibin B (INHB) Enzyme-linked immunosorbent assay for Antigen Detection.
CEA760Hu ELISA Kit for Inhibin B (INHB) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA760Hu Magnetic Luminex Assay Kit for Inhibin B (INHB) ,etc. Magnetic Luminex Assay for Antigen Detection.
전체 세부 정보 보기