SKU(재고 관리 코드):CEB653Mu
ELISA Kit for Myostatin (MSTN)
ELISA Kit for Myostatin (MSTN)
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
CEB653Mu
Organism Species
Mus musculus (Mouse).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Competitive Inhibition
Assay Length
2h
Detection Range
617.3-50,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 274.3pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Myostatin (MSTN).
No significant cross-reactivity or interference between Myostatin (MSTN) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Myostatin (MSTN) and the recovery rates were calculated by comparing the measured value to the expected amount of Myostatin (MSTN) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-90 | 85 |
EDTA plasma(n=5) | 79-101 | 83 |
heparin plasma(n=5) | 83-92 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myostatin (MSTN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myostatin (MSTN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myostatin (MSTN) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-98% | 81-104% | 81-101% | 78-104% |
EDTA plasma(n=5) | 78-105% | 79-92% | 98-105% | 78-103% |
heparin plasma(n=5) | 78-94% | 90-98% | 96-103% | 89-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Magazine | Citations |
Clinical Medicine and Diagnostics | Anti-Myostatin Reduces Bone Mineral Loss in Ovariectomized Rats Sapub:Source |
Nutr Metab (Lond) | Short-term, high-fat diet accelerates disuse atrophy and protein degradation in a muscle-specific manner in mice PubMed: 26539241 |
International Journal of Cancer | Tumor inoculation site affects the development of cancer cachexia and muscle wasting PubMed: 26016447 |
Connect Tissue Res | Induction of transient tenogenic phenotype of high density cultured human dermal fibroblasts PubMed: 25748814 |
PLoS One | Higher Plasma Myostatin Levels in Cor Pulmonale Secondary to Chronic Obstructive Pulmonary Disease Pubmed:26998756 |
Calcif Tissue Int. | The Effect of Vibration Treatments Combined with Teriparatide or Strontium Ranelate on Bone Healing and Muscle in Ovariectomized Rats Pubmed:27272029 |
Archives of medical research | Irisin and Myostatin Levels in Patients with Graves' Disease. pubmed:27986127 |
Calcified Tissue International | Effect of Strontium Ranelate on the Muscle and Vertebrae of Ovariectomized Rats pubmed:29242963 |
Scientific Reports | Compensatory anabolic signaling in the sarcopenia of experimental chronic arthritis. pubmed:28740214 |
Journal of Animal Science | Fermented corn-soybean meal elevated IGF1 levels in grower-finisher pigs Pubmed: 30203098 |
European Journal of Internal Medicine | Predictive value of serum myostatin for the severity and clinical outcome of heart failure Pubmed: 31056368 |
J Cell Physiol | Resistance training‐induced muscle hypertrophy is mediated by TGF‐β1‐Smad signaling pathway in male Wistar rats Pubmed: 31960436 |
NEPHROLOGY DIALYSIS TRANSPLANTATION | Myostatin and muscle atrophy during chronic kidney disease Pubmed: 32974666 |
Oxid Med Cell Longev | Gender-Specific Behaviour in Obesity Stages I-II: Imbalance of Aminothiol Status and Adipomyokine Profile in Subjects with Different Insulin Resistance … 34868459 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPB653Mu02 | Recombinant Myostatin (MSTN) | Positive Control; Immunogen; SDS-PAGE; WB. |
APB653Mu01 | Active Myostatin (MSTN) | Cell culture; Activity Assays. |
RPB653Mu01 | Recombinant Myostatin (MSTN) | Positive Control; Immunogen; SDS-PAGE; WB. |
CPB653Mu21 | OVA Conjugated Myostatin (MSTN) | Immunogen; SDS-PAGE; WB. |
PAB653Mu08 | Polyclonal Antibody to Myostatin (MSTN) | WB; IHC; ICC; IP. |
PAB653Mu02 | Polyclonal Antibody to Myostatin (MSTN) | WB; IHC; ICC; IP. |
PAB653Mu01 | Polyclonal Antibody to Myostatin (MSTN) | WB; IHC; ICC; IP. |
LAB653Mu71 | Biotin-Linked Polyclonal Antibody to Myostatin (MSTN) | WB; IHC; ICC. |
SEB653Mu | ELISA Kit for Myostatin (MSTN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEB653Mu | ELISA Kit for Myostatin (MSTN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB653Mu | Magnetic Luminex Assay Kit for Myostatin (MSTN) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSB653Mu11 | ELISA Kit DIY Materials for Myostatin (MSTN) | Main materials for "Do It (ELISA Kit) Yourself". |