ELISA Kit for 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR)
ELISA Kit for 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR)
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SED686Hu
Organism Species
Homo sapiens (Human).
Sample Type
Tissue homogenates, cell lysates and other biological fluids
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
1.56-100ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.59ng/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR).
No significant cross-reactivity or interference between 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Magazine | Citations |
Neuroscience | 27-Hydroxycholesterol contributes to disruptive effects on learning and memory by modulating cholesterol metabolism in the rat brain PubMed: 25987203 |
Neurotoxicology. | 27-Hydroxycholesterol regulates cholesterol synthesis and transport in C6 glioma cells. pubmed:28167099 |
archives of medical research | Transthyretin Regulated by linc00657/miR-205-5p Promoted Cholesterol Metabolism by Inducing SREBP2-HMGCR and Inhibiting LXRα-CYP7A1 Pubmed: 32241558 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
PAD686Hu01 | Polyclonal Antibody to 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) | WB; IHC; ICC; IP. |
SED686Hu | ELISA Kit for 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMD686Hu | Magnetic Luminex Assay Kit for 3-Hydroxy-3-Methylglutaryl Coenzyme A Reductase (HMGCR) ,etc. | Magnetic Luminex Assay for Antigen Detection. |