SKU(재고 관리 코드):SEA998Ra
ELISA Kit for Glypican 4 (GPC4)
ELISA Kit for Glypican 4 (GPC4)
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
SEA998Ra
Organism Species
Rattus norvegicus (Rat).
Sample Type
Serum, plasma, tissue homogenates and other biological fluids.
Test Method
Double-antibody Sandwich
Assay Length
3h
Detection Range
15.6-1,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 6.1pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Glypican 4 (GPC4).
No significant cross-reactivity or interference between Glypican 4 (GPC4) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glypican 4 (GPC4) and the recovery rates were calculated by comparing the measured value to the expected amount of Glypican 4 (GPC4) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 84-93 | 89 |
EDTA plasma(n=5) | 93-101 | 98 |
heparin plasma(n=5) | 98-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glypican 4 (GPC4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glypican 4 (GPC4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glypican 4 (GPC4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 96-104% | 83-94% | 99-105% | 84-93% |
EDTA plasma(n=5) | 91-101% | 93-101% | 93-101% | 78-102% |
heparin plasma(n=5) | 81-89% | 86-93% | 90-98% | 89-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Magazine | Citations |
PLoS One. | Identification of adipokine clusters related to parameters of fat mass, insulin sensitivity and inflammation Pubmed:Pmc4072672 |
Aspects of fluid therapy in the critically ill. Experimental and clinical studies on fluid therapy in the inflammatory conditions. 250690_2_G5_Svajunas_S.pdf | |
Intensive Care Medicine Experimental | Elevated plasma glypicans are associated with organ failure in patients with infection Pubmed: 30618011 |
Crit Care | Albumin infusion rate and plasma volume expansion: a randomized clinical trial in postoperative patients after major surgery Pubmed: 31138247 |
J Endocrinol Invest | Serum glypican4 and glycosylphosphatidylinositol-specific phospholipase D levels are associated with adipose tissue insulin resistance in obese subjects with … Pubmed: 32816247 |
Heparin Binding Protein and Endothelial Glycocalyx Markers in Severe COVID-19–A Prospective Observational Cohort Study | |
Sci Rep | Glypican-4 in pregnancy and its relation to glucose metabolism, insulin resistance and gestational diabetes mellitus status 34903856 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA998Ra01 | Recombinant Glypican 4 (GPC4) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA998Ra01 | Polyclonal Antibody to Glypican 4 (GPC4) | WB; IHC; ICC; IP. |
SEA998Ra | ELISA Kit for Glypican 4 (GPC4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA998Ra | Magnetic Luminex Assay Kit for Glypican 4 (GPC4) ,etc. | Magnetic Luminex Assay for Antigen Detection. |