SKU(재고 관리 코드):CEB067Po
ELISA Kit for Peptide YY (PYY)
ELISA Kit for Peptide YY (PYY)
Enzyme-linked immunosorbent assay for Antigen Detection.
Product No.
CEB067Po
Organism Species
Sus scrofa; Porcine (Pig).
Sample Type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Test Method
Competitive Inhibition
Assay Length
2h
Detection Range
12.35-1,000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 5.34pg/mL.
UOM
48T 96T 96T*5 96T*10 96T*100
Specificity
This assay has high sensitivity and excellent specificity for detection of Peptide YY (PYY).
No significant cross-reactivity or interference between Peptide YY (PYY) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Peptide YY (PYY) and the recovery rates were calculated by comparing the measured value to the expected amount of Peptide YY (PYY) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-99 | 89 |
EDTA plasma(n=5) | 80-90 | 82 |
heparin plasma(n=5) | 94-102 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Peptide YY (PYY) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Peptide YY (PYY) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Peptide YY (PYY) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-93% | 82-96% | 91-101% | 80-99% |
EDTA plasma(n=5) | 78-91% | 79-102% | 78-88% | 94-101% |
heparin plasma(n=5) | 85-99% | 86-95% | 94-102% | 96-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Magazine | Citations |
International Journal of Sport Studies | The Effects of Concurrent Resistance and Endurance Exercise on Hunger Feelings and PYY in Obese Men Com:Source |
Annals of Applied Sport Science | Effect of an Acute Incremental Exercise on Plasma Peptide YY, Neuropeptide Y and IGF-1 Concentrations in Young Athletes Aassjournal:Source |
Biomedical Reports | Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents. pubmed:28413639 |
Acta Diabetologica | Effect of lifestyle improvement program on the biomarkersof adiposity, inflammation and gut hormones in overweight/obese Asian Indians with prediabetes pubmed:28620678 |
Biomedical Reports | Calprotectin in serum and zonulin in serum and feces are elevated after introduction of a diet with lower carbohydrate content and higher fiber, fat and protein contents 10.3892/br.2017.865 |
Journal of Diabetes & Metabolism | High Fiber Fat and Protein Contents Lead to Increased Satiety Reduced Sweet Cravings and Decreased Gastrointestinal Symptoms Independently of Anthropometric Hormonal and Metabolic Factors 10.4172/2155-6156.1000733 |
Frontiers in Physiology | Ileal Transposition Surgery Decreases Fat Mass and Improves Glucose Metabolism in Diabetic GK Rats: Possible Involvement of FGF21 Pubmed:29593555 |
Food and Nutrition Research | Alignments of endocrine, anthropometric, and metabolic parameters in type 2 diabetes after intervention with an Okinawa-based Nordic diet Pubmed:29599686 |
The Journal of Nutrition | Grape Seed Proanthocyanidin Affects Lipid Metabolism via Changing Gut Microflora and Enhancing Propionate Production in Weaned Pigs Pubmed: 31175811 |
The Journal of Nutritional Biochemistry | Bile acid receptor TGR5 is critically involved in preference for dietary lipids and obesity Pubmed: 31812910 |
Arch Toxicol | Serotonin involvement in okadaic acid-induced diarrhoea in vivo 34148100 |
foods | Appetite and Satiety Effects of the Acute and Regular Consumption of Green Coffee Phenols and Green Coffee Phenol/Oat β-Glucan Nutraceuticals in Subjects with … 34828792 |
Catalog No. | Related products for research use of Sus scrofa; Porcine (Pig) Organism species | Applications (RESEARCH USE ONLY!) |
RPB067Po01 | Recombinant Peptide YY (PYY) | Positive Control; Immunogen; SDS-PAGE; WB. |
CPB067Po21 | OVA Conjugated Peptide YY (PYY) | Immunogen; SDS-PAGE; WB. |
PAB067Po01 | Polyclonal Antibody to Peptide YY (PYY) | WB; IHC; ICC; IP. |
MAB067Po21 | Monoclonal Antibody to Peptide YY (PYY) | WB; IHC; ICC; IP. |
CEB067Po | ELISA Kit for Peptide YY (PYY) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB067Po | Magnetic Luminex Assay Kit for Peptide YY (PYY) ,etc. | Magnetic Luminex Assay for Antigen Detection. |