1
/
의
1
ELK Biotechnology
SKU(재고 관리 코드):ELK7917
Pig C5b-9(Terminal Complement Complex C5b-9) ELISA Kit
Pig C5b-9(Terminal Complement Complex C5b-9) ELISA Kit
Pig C5b-9(Terminal Complement Complex C5b-9) ELISA Kit
Overview
| Product name: | Pig sC5b-9(Soluble Terminal Complement Complex C5b-9) ELISA Kit |
| Reactivity: | Pig |
| Alternative Names: | MAC; Membrane Attack Complex; C5b-9; Terminal Complement Complex C5b-9; C5b9 |
| Assay Type: | Sandwich |
| Sensitivity: | 0.32 ng/mL |
| Standard: | 50 ng/mL |
| Range: | 0.79-50 ng/mL |
| Sample Type: | Plasma, tissue homogenates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | Signal transduction;Metabolic pathway;Apoptosis;Infection immunity; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Pig sC5b-9. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Pig sC5b-9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Pig sC5b-9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Pig sC5b-9 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 50.00 | 2.043 | 1.971 |
| 25.00 | 1.643 | 1.571 |
| 12.50 | 1.186 | 1.114 |
| 6.25 | 0.752 | 0.680 |
| 3.13 | 0.527 | 0.455 |
| 1.57 | 0.321 | 0.249 |
| 0.79 | 0.206 | 0.134 |
| 0.00 | 0.072 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant sC5b-9 and the recovery rates were calculated by comparing the measured value to the expected amount of sC5b-9 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 95-107% | 101% |
| EDTA plasma(n=5) | 77-95% | 86% |
| Heparin plasma(n=5) | 84-97% | 90% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of sC5b-9 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-92% | 88-96% | 87-98% | 95-102% |
| EDTA plasma(n=5) | 85-101% | 84-98% | 85-93% | 86-98% |
| Heparin plasma(n=5) | 86-93% | 91-105% | 87-98% | 89-94% |