Rabbit COL5(Collagen Type V) ELISA Kit

Sensitivity

Rabbit COL5(Collagen Type V) ELISA Kit

Overview

Product name: Rabbit COL5(Collagen Type V) ELISA Kit
Reactivity: Rabbit
Alternative Names: Collagen Type V
Assay Type: Sandwich
Sensitivity: 1.032 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Developmental science;Nutrition metabolism;Bone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rabbit COL5. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rabbit COL5. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rabbit COL5, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rabbit COL5 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
200.00 2.154 2.056
100.00 1.593 1.495
50.00 1.251 1.153
25.00 0.907 0.809
12.50 0.496 0.398
6.25 0.397 0.299
3.13 0.230 0.132
0.00 0.098 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant COL5 and the recovery rates were calculated by comparing the measured value to the expected amount of COL5 in samples.
Matrix Recovery range Average
serum(n=5) 78-95% 86%
EDTA plasma(n=5) 81-95% 88%
Heparin plasma(n=5) 82-98% 90%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of COL5 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 88-104% 97-108% 83-97%
EDTA plasma(n=5) 84-99% 95-102% 91-103% 86-92%
Heparin plasma(n=5) 88-97% 89-97% 79-94% 87-96%