SKU(재고 관리 코드):ELK9699
Rabbit sC5b-9(Soluble Terminal Complement Complex C5b-9) ELISA Kit
Rabbit sC5b-9(Soluble Terminal Complement Complex C5b-9) ELISA Kit
Rabbit sC5b-9(Soluble Terminal Complement Complex C5b-9) ELISA Kit
Overview
Product name: | Rabbit sC5b-9(Soluble Terminal Complement Complex C5b-9) ELISA Kit |
Reactivity: | Rabbit |
Alternative Names: | MAC; Membrane Attack Complex; C5b-9; Terminal Complement Complex C5b-9; C5b9 |
Assay Type: | Sandwich |
Sensitivity: | 0.10 ng/mL |
Standard: | 10 ng/mL |
Detection Range: | 0.16-10 ng/mL |
Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay Length: | 3.5h |
Research Area: | Immunology;Metabolism;Signal Transduction |
Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rabbit sC5b-9. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rabbit sC5b-9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rabbit sC5b-9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rabbit sC5b-9 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
10.00 | 2.054 | 1.959 |
5.00 | 1.612 | 1.517 |
2.50 | 1.211 | 1.116 |
1.25 | 0.933 | 0.838 |
0.63 | 0.559 | 0.464 |
0.32 | 0.385 | 0.290 |
0.16 | 0.186 | 0.091 |
0.00 | 0.095 | 0.000 |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant sC5b-9 and the recovery rates were calculated by comparing the measured value to the expected amount of sC5b-9 in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 85-101% | 93% |
EDTA plasma(n=5) | 78-92% | 85% |
Heparin plasma(n=5) | 87-99% | 93% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of sC5b-9 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 99-106% | 78-92% | 83-97% | 85-93% |
EDTA plasma(n=5) | 98-105% | 87-98% | 91-99% | 85-93% |
Heparin plasma(n=5) | 82-95% | 93-99% | 85-97% | 83-96% |