1
/
의
1
ELK Biotechnology
SKU(재고 관리 코드):ELK6268
Rat BAFF(B-Cell Activating Factor) ELISA Kit
Rat BAFF(B-Cell Activating Factor) ELISA Kit
Rat BAFF(B-Cell Activating Factor) ELISA Kit
Overview
| Product name: | Rat BAFF/CD257(B-Cell Activating Factor) ELISA Kit |
| Reactivity: | Rat |
| Alternative Names: | CD257; TNFSF13B; BLYS; TALL1; THANK; TNFSF20; ZTNF4; B lymphocyte stimulator; Tumor Necrosis Factor Ligand Superfamily Member 13B; Dendritic cell-derived TNF-like; BAFF |
| Assay Type: | Sandwich |
| Sensitivity: | 27 pg/mL |
| Standard: | 5000 pg/mL |
| Detection Range: | 78.13-5000 pg/mL |
| Sample Type: | Serum, plasma, tissue homogenates, cell lysates and other biological fluids |
| Assay Length: | 3.5h |
| Research Area: | CD & Adhesion molecule;Tumor immunity;Infection immunity;Immune molecule; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat BAFF/CD257. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat BAFF/CD257. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat BAFF/CD257, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat BAFF/CD257 in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 5000.00 | 2.132 | 2.045 |
| 2500.00 | 1.579 | 1.492 |
| 1250.00 | 1.067 | 0.980 |
| 625.00 | 0.875 | 0.788 |
| 312.50 | 0.516 | 0.429 |
| 156.25 | 0.323 | 0.236 |
| 78.13 | 0.235 | 0.148 |
| 0.00 | 0.087 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant BAFF/CD257 and the recovery rates were calculated by comparing the measured value to the expected amount of BAFF/CD257 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 78-96% | 87% |
| EDTA plasma(n=5) | 95-107% | 101% |
| Heparin plasma(n=5) | 82-95% | 88% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BAFF/CD257 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 85-103% | 82-96% | 87-105% | 90-99% |
| EDTA plasma(n=5) | 79-93% | 86-92% | 84-98% | 89-102% |
| Heparin plasma(n=5) | 85-97% | 93-101% | 97-103% | 91-99% |
Share