| Product name: | Rat EG-VEGF(Endocrine Gland Derived Vascular Endothelial Growth Factor) ELISA Kit |
| Reactivity: | Rat |
| Alternative Names: | PK1; EGVEGF; PRK1, PROK1; Prokineticin 1; Black Mamba Toxin-Related Protein; Mambakine |
| Assay Type: | Sandwich |
| Sensitivity: | 6.5 pg/mL |
| Standard: | 1000 pg/mL |
| Range: | 15.63-1000 pg/mL |
| Sample Type: | Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids. |
| Assay Length: | 3.5h |
| Research Area: | Cytokine;Tumor immunity; |
| Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat EG-VEGF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat EG-VEGF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat EG-VEGF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat EG-VEGF in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 1000.00 | 2.332 | 2.228 |
| 500.00 | 1.628 | 1.524 |
| 250.00 | 1.225 | 1.121 |
| 125.00 | 0.782 | 0.678 |
| 62.50 | 0.509 | 0.405 |
| 31.25 | 0.319 | 0.215 |
| 15.63 | 0.228 | 0.124 |
| 0.00 | 0.104 | 0.000 |

Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant EG-VEGF and the recovery rates were calculated by comparing the measured value to the expected amount of EG-VEGF in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 81-97% | 89% |
| EDTA plasma(n=5) | 85-97% | 91% |
| Heparin plasma(n=5) | 79-97% | 88% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of EG-VEGF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 86-96% | 93-104% | 89-97% | 85-94% |
| EDTA plasma(n=5) | 87-96% | 85-97% | 85-94% | 87-96% |
| Heparin plasma(n=5) | 92-101% | 82-98% | 89-97% | 85-93% |