SKU(재고 관리 코드):ELK9627
Simian OC/BGP(Osteocalcin) ELISA Kit
Simian OC/BGP(Osteocalcin) ELISA Kit
Simian OC/BGP(Osteocalcin) ELISA Kit
Overview
Product name: | Simian OC/BGP(Osteocalcin) ELISA Kit |
Reactivity: | Simian |
Alternative Names: | BGLAP; BGP; OC; OCN; bone gamma-carboxyglutamate protein; Osteocalcin |
Assay Type: | Sandwich |
Sensitivity: | 0.47 ng/mL |
Standard: | 50 ng/mL |
Detection Range: | 0.78-50 ng/mL |
Sample Type: | serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay Length: | 3.5h |
Research Area: | Stem Cells;Signal Transduction; |
Test principle: | The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Simian OC/BGP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Simian OC/BGP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Simian OC/BGP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Simian OC/BGP in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
50.00 | 2.266 | 2.171 |
25.00 | 1.593 | 1.498 |
12.50 | 1.228 | 1.133 |
6.25 | 0.757 | 0.662 |
3.13 | 0.563 | 0.468 |
1.57 | 0.318 | 0.223 |
0.79 | 0.236 | 0.141 |
0.00 | 0.095 | 0.000 |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant OC/BGP and the recovery rates were calculated by comparing the measured value to the expected amount of OC/BGP in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 78-96% | 87% |
EDTA plasma(n=5) | 82-95% | 88% |
Heparin plasma(n=5) | 90-103% | 96% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OC/BGP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 88-97% | 87-103% | 81-93% | 79-92% |
EDTA plasma(n=5) | 89-102% | 87-98% | 80-92% | 98-105% |
Heparin plasma(n=5) | 84-99% | 87-96% | 88-97% | 89-102% |