SKU(재고 관리 코드):ELK9416
Zebrafish 5-HT(5-Hydroxytryptamine) ELISA Kit
Zebrafish 5-HT(5-Hydroxytryptamine) ELISA Kit
Zebrafish 5-HT(5-Hydroxytryptamine) ELISA Kit
Overview
Product name: | Zebrafish 5-HT(5-Hydroxytryptamine) ELISA Kit |
Reactivity: | Zebrafish |
Alternative Names: | 5HT; Serotonin; N-Methyl-Gamma |
Assay Type: | Competitive Inhibition |
Sensitivity: | 3.97 ng/mL |
Standard: | 900 ng/mL |
Detection Range: | 14.07-900 ng/mL |
Sample Type: | serum, plasma, tissue homogenates |
Assay Length: | 2h |
Research Area: | Signal transduction;Infection immunity;Neuro science;Gastroenterology; |
Test principle: | This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Zebrafish 5-HT protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Zebrafish 5-HT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Zebrafish 5-HT in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard curve
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
900.00 | 0.232 | — |
450.00 | 0.385 | — |
225.00 | 0.696 | — |
112.50 | 0.823 | — |
56.25 | 1.275 | — |
28.13 | 1.592 | — |
14.07 | 1.887 | — |
0.00 | 2.123 | — |
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant 5-HT and the recovery rates were calculated by comparing the measured value to the expected amount of 5-HT in samples.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 85-99% | 92% |
EDTA plasma(n=5) | 90-105% | 97% |
Heparin plasma(n=5) | 95-107% | 101% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 5-HT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 89-102% | 87-95% | 85-96% | 92-102% |
EDTA plasma(n=5) | 81-92% | 86-93% | 91-103% | 81-94% |
Heparin plasma(n=5) | 86-98% | 92-101% | 95-104% | 87-96% |