SKU(재고 관리 코드):ELK9690

Zebrafish NT3(Neurotrophin 3) ELISA Kit

Zebrafish NT3(Neurotrophin 3) ELISA Kit

Sensitivity

Zebrafish NT3(Neurotrophin 3) ELISA Kit

Overview

Product name: Zebrafish NT3(Neurotrophin 3) ELISA Kit
Reactivity: Zebrafish
Alternative Names: NTF3; HDNF; NGF2; Nerve Growth Factor 2; Neurotrophic Factor
Assay Type: Sandwich
Sensitivity: 30 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Neuro science;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Zebrafish NT3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Zebrafish NT3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Zebrafish NT3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Zebrafish NT3 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
5000.00 2.266 2.187
2500.00 1.612 1.533
1250.00 1.196 1.117
625.00 0.839 0.760
312.50 0.532 0.453
156.25 0.313 0.234
78.13 0.236 0.157
0.00 0.079 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant NT3 and the recovery rates were calculated by comparing the measured value to the expected amount of NT3 in samples.
Matrix Recovery range Average
serum(n=5) 92-106% 99%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 78-97% 87%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NT3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 82-101% 93-105% 88-96%
EDTA plasma(n=5) 90-101% 93-102% 88-102% 86-92%
Heparin plasma(n=5) 81-93% 89-104% 95-104% 79-92%